General specifications | |
|---|---|
| Type | Inclination sensor, 1-axis |
| Measurement range | 0 ... 360 ° |
| Absolute accuracy | ? ± 0.5 ° |
| Response delay | ? 20 ms |
| Resolution | ? 0.1 ° |
| Repeat accuracy | ? ± 0.1 ° |
| Temperature influence | ? 0.027 °/K |
Functional safety related parameters | |
| MTTFd | 300 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Indicators/operating means | |
| Operation indicator | LED, green |
| Teach-In indicator | 2 LEDs yellow (switching status), flashing |
| Button | 2 push-buttons ( Switch points programming , Evaluation range programming ) |
| Switching state | 2 yellow LEDs: Switching status (each output) |
Electrical specifications | |
| Operating voltage | 10 ... 30 V DC |
| No-load supply current | ? 25 mA |
| Time delay before availability | ? 200 ms |
Switching output | |
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected |
| Operating current | ? 100 mA |
| Voltage drop | ? 3 V |
Analog output | |
| Output type | 1 current output 4 ... 20 mA |
| Load resistor | 0 ... 200 ? at UB = 10 ... 18 V 0 ... 500 ? at UB = 18 ... 30 V |
Compliance with standards and directives | |
| Standard conformity | |
Approvals and certificates | |
| UL approval | cULus Listed, Class 2 Power Source |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source |
| CCC approval | CCC approval / marking not required for products rated ?36 V |
| E1 Type approval | 10R-04 |
Ambient conditions | |
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications | |
| Connection type | 7 m, PUR cable 5 x 0.5 mm2 |
| Housing material | PA |
| Degree of protection | IP68 / IP69K |
| Mass | 240 g |
Factory settings | |
| Switching output 1 | -30 ° ... 30 ° |
| Switching output 2 | -30 ° ... 30 ° |
| Analog output | -45 ° ... 45 ° |
8 (029) 555-8-000 | |